典型变电站的闪络毁伤仿真分析

Simulation Analysis for Flashover Damage of a Typical Substation

  • 摘要: 研究闪络毁伤作用下典型变电站的毁伤响应特性. 以500 kV枢纽变电站为研究对象,在对变电站功能、构成及运行特点进行分析的基础上,提出了变电站毁伤等级划分方法和毁伤效果评价指标;利用电磁暂态仿真软件PSCAD建立变电站仿真模型,完成了各电气设备毁伤致变电站毁伤的模拟计算,定量描述了电气设备毁伤与变电站毁伤的关系. 研究结果为变电站目标易损性评估,反电力系统闪络毁伤战斗部的毁伤效能研究及攻击方案规划提供了基础和依据.

     

    Abstract: The response characteristics of typical substation under flashover damage were investigated. The characteristics and vulnerability of a typical 500 kV pivotal substation were analyzed in this paper. The classification method of substation damage grade was proposed, and the damage effect evaluation index was defined on the basis of analyzing the function, structure and operation characteristics of substation. The electromagnetic transient simulation software PSCAD was used to establish the simulation model of substation. The simulations of substation damage caused by electrical equipment damage were conducted. It provided a foundation and basis for substation target vulnerability assessment, attack damage effectiveness evaluation and scheme planning of anti-power system flashover damage warhead.

     

/