TY - JOUR
T1 - Aptamer-functionalized 2D photonic crystal hydrogels for sensitive and selective Hg2+detection
AU - Gao, Shiyu
AU - Xue, Yuhan
AU - Liu, Yangyang
AU - Jing, Jing
AU - Meng, Zihui
AU - Geng, Junming
AU - Zhang, Xiaoling
N1 - Publisher Copyright:
© 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
PY - 2026/6/15
Y1 - 2026/6/15
N2 - A two-dimensional photonic crystal hydrogel (2DPCH) sensor functionalized with aptamers has been developed for the highly sensitive detection of Hg2+ in water. The sensing mechanism relies on the specific formation of T- Hg2+-T hairpin structures between Hg2+ and the aptamers, inducing hydrogel contraction and altering the spacing between embedded two-dimensional photonic crystal microspheres. The Hg2+ concentration is determined by measuring changes in the diameter of the Debye diffraction rings. This method exhibits a detection range from 1 nM to 1 mM, with a limit of detection (LOD) of 0.65 nM and a strong linear correlation (R² = 0.9933). The sensor can be regenerated using 1 M HCl and reused multiple times without significant performance degradation. In spiked lake water samples, recovery rates ranged from 94.23% to 101.10%, with relative standard deviations (RSD) between 0.29% and 2.55%. This sensor demonstrates high sensitivity, excellent selectivity, reversibility, and requires only a laser pointer for operation, offering a novel strategy for the on-site rapid detection of heavy metal ions.
AB - A two-dimensional photonic crystal hydrogel (2DPCH) sensor functionalized with aptamers has been developed for the highly sensitive detection of Hg2+ in water. The sensing mechanism relies on the specific formation of T- Hg2+-T hairpin structures between Hg2+ and the aptamers, inducing hydrogel contraction and altering the spacing between embedded two-dimensional photonic crystal microspheres. The Hg2+ concentration is determined by measuring changes in the diameter of the Debye diffraction rings. This method exhibits a detection range from 1 nM to 1 mM, with a limit of detection (LOD) of 0.65 nM and a strong linear correlation (R² = 0.9933). The sensor can be regenerated using 1 M HCl and reused multiple times without significant performance degradation. In spiked lake water samples, recovery rates ranged from 94.23% to 101.10%, with relative standard deviations (RSD) between 0.29% and 2.55%. This sensor demonstrates high sensitivity, excellent selectivity, reversibility, and requires only a laser pointer for operation, offering a novel strategy for the on-site rapid detection of heavy metal ions.
KW - Aptamer
KW - Hydrogel sensor
KW - Mercury ion detection
KW - Two-dimensional photonic crystal
UR - https://www.scopus.com/pages/publications/105036860716
U2 - 10.1016/j.jhazmat.2026.142176
DO - 10.1016/j.jhazmat.2026.142176
M3 - Article
AN - SCOPUS:105036860716
SN - 0304-3894
VL - 511
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
M1 - 142176
ER -