TY - JOUR
T1 - End-to-end Donaldson matrix estimation from fluorescence emission under programmable multi-illumination excitation using a hybrid CNN-transformer model
AU - Yuan, Yue
AU - Sun, Ruoduan
AU - Liao, Lingyu
AU - Li, Juntao
AU - Ma, Shining
AU - Wang, Lizhi
AU - Liu, Yue
AU - Huang, Hua
AU - Song, Weitao
N1 - Publisher Copyright:
© 2026
PY - 2026/5/12
Y1 - 2026/5/12
N2 - Donaldson matrix serves as a fundamental tool for fluorescence characterization. Currently, conventional acquisition of the Donaldson matrix via double-monochromator method is time-consuming, expensive, and inefficient, limiting its widespread application. To address this, we introduce a new measurement paradigm that shifts the complexity from exhaustive hardware scanning to intelligent computational inference. This can be achieved through a synergistic system coupling a digital micromirror device (DMD)-based programmable light source with a dedicated CNN-Transformer model. The system computationally reconstructs the complete Donaldson matrix from a minimal set of just 5–6 spectrally rich excitations in an end-to-end manner, eliminating the need for complex preprocessing. Quantitative evaluations under diverse combinations of broadband and narrowband light sources demonstrate robust performance across varying excitation conditions. The model generalizes well to samples with single and dual fluorophores, covering near-UV to visible excitation ranges, maintaining median RMSE values within 0.03 in both reflectance and fluorescence dominant regions. Additionally, the model's generalization is demonstrated by its ability to accurately estimate analogous spectral radiance factor matrices under various standard illuminants. By anchoring the model to ground-truth data from a reference double-monochromator, our approach ensures full metrological traceability, achieving an expanded uncertainty of 0.062 (k = 2) as per GUM guidelines. The proposed end-to-end measurement paradigm streamlines fluorescence characterization by directly estimating the Donaldson matrix from raw spectral inputs. Its generalization across various illuminations and samples with diverse spectral features suggests significant potential for practical fluorescence analysis under a wide range of experimental conditions.
AB - Donaldson matrix serves as a fundamental tool for fluorescence characterization. Currently, conventional acquisition of the Donaldson matrix via double-monochromator method is time-consuming, expensive, and inefficient, limiting its widespread application. To address this, we introduce a new measurement paradigm that shifts the complexity from exhaustive hardware scanning to intelligent computational inference. This can be achieved through a synergistic system coupling a digital micromirror device (DMD)-based programmable light source with a dedicated CNN-Transformer model. The system computationally reconstructs the complete Donaldson matrix from a minimal set of just 5–6 spectrally rich excitations in an end-to-end manner, eliminating the need for complex preprocessing. Quantitative evaluations under diverse combinations of broadband and narrowband light sources demonstrate robust performance across varying excitation conditions. The model generalizes well to samples with single and dual fluorophores, covering near-UV to visible excitation ranges, maintaining median RMSE values within 0.03 in both reflectance and fluorescence dominant regions. Additionally, the model's generalization is demonstrated by its ability to accurately estimate analogous spectral radiance factor matrices under various standard illuminants. By anchoring the model to ground-truth data from a reference double-monochromator, our approach ensures full metrological traceability, achieving an expanded uncertainty of 0.062 (k = 2) as per GUM guidelines. The proposed end-to-end measurement paradigm streamlines fluorescence characterization by directly estimating the Donaldson matrix from raw spectral inputs. Its generalization across various illuminations and samples with diverse spectral features suggests significant potential for practical fluorescence analysis under a wide range of experimental conditions.
KW - Computational spectroscopy
KW - Deep learning
KW - Donaldson matrix
KW - Fluorescence characterization
UR - https://www.scopus.com/pages/publications/105033430011
U2 - 10.1016/j.measurement.2026.121199
DO - 10.1016/j.measurement.2026.121199
M3 - Article
AN - SCOPUS:105033430011
SN - 0263-2241
VL - 273
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 121199
ER -