T1 - Optimal phase-transfer-enabled high-fidelity Fourier ptychographic quantitative phase imaging
AU - Zheng, Chuanjian
AU - Wang, Han
AU - Chen, Zixuan
AU - Li, Xiaoqiong
AU - Hao, Qun
AU - Zhang, Shaohui
N1 - Publisher Copyright:
© 2026 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement.
PY - 2026/3/20
Y1 - 2026/3/20
N2 - Fourier ptychographic quantitative phase imaging (FP-QPI) is a promising label-free microscopy technique that has shown broad applications in biomedicine owing to its large-field and high-resolution imaging features. However, the low-frequency components of the phase spectrum cannot be transferred into detectable intensity variations when the illumination angle is smaller than the maximal acceptance angle of the objective. As a result, phase underestimation occurs, inherently degrading the fidelity of FP-QPI. Here, we present optimal phase-transfer-enabled FP-QPI (OFP-QPI) to address this issue by complementarily combining defocus modulation and angle-varied illumination into each intensity measurement at a single defocus plane. Low-frequency phase-to-intensity transfer from defocus modulation and data redundancy from angle-varied illumination collectively enable full phase spectrum reconstruction, thus providing high-fidelity imaging results. We develop a strategy to determine the optimal phase transfer and demonstrate that OFP-QPI reduces the phase imaging error from 52.2% to 11.3%. Experiments on RHNC cells validate the capability of OFP-QPI to perform large-field and long-term cell observation. These results indicate that OFP-QPI enables high-fidelity quantitative phase imaging over extended time scales, making it well suited for long-term, label-free studies of dynamic cellular processes.
AB - Fourier ptychographic quantitative phase imaging (FP-QPI) is a promising label-free microscopy technique that has shown broad applications in biomedicine owing to its large-field and high-resolution imaging features. However, the low-frequency components of the phase spectrum cannot be transferred into detectable intensity variations when the illumination angle is smaller than the maximal acceptance angle of the objective. As a result, phase underestimation occurs, inherently degrading the fidelity of FP-QPI. Here, we present optimal phase-transfer-enabled FP-QPI (OFP-QPI) to address this issue by complementarily combining defocus modulation and angle-varied illumination into each intensity measurement at a single defocus plane. Low-frequency phase-to-intensity transfer from defocus modulation and data redundancy from angle-varied illumination collectively enable full phase spectrum reconstruction, thus providing high-fidelity imaging results. We develop a strategy to determine the optimal phase transfer and demonstrate that OFP-QPI reduces the phase imaging error from 52.2% to 11.3%. Experiments on RHNC cells validate the capability of OFP-QPI to perform large-field and long-term cell observation. These results indicate that OFP-QPI enables high-fidelity quantitative phase imaging over extended time scales, making it well suited for long-term, label-free studies of dynamic cellular processes.
UR - https://www.scopus.com/pages/publications/105033184442
U2 - 10.1364/OPTICA.586545
DO - 10.1364/OPTICA.586545
M3 - Article
AN - SCOPUS:105033184442
SN - 2334-2536
VL - 13
SP - 434
EP - 442
JO - Optica
JF - Optica
IS - 3
ER -