TY - JOUR
T1 - Refinement-based noise-conditioned learning for semi-supervised medical image segmentation
AU - Meng, Qingxu
AU - Wang, Weijiang
AU - Qi, Hang
AU - Dang, Hua
AU - Shan, Chuxuan
AU - Gu, Jiacheng
AU - Wang, Dan
AU - Wang, Xiaohua
N1 - Publisher Copyright:
© 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
PY - 2026/8/1
Y1 - 2026/8/1
N2 - Semi-supervised medical image segmentation aims to reduce annotation costs by exploiting unlabeled data, yet its performance is often limited by unreliable pseudo-label supervision. In existing studies, V-Net and its variants are predominantly adopted as backbone architectures, and most advances focus on improving training strategies rather than exploring architectural diversity. We observe that directly applying classical segmentation models to semi-supervised settings, without task-specific configuration adjustment, often leads to overfitting when models are trained to predict segmentation masks from scratch. Interestingly, our empirical analysis reveals that reformulating the same segmentation models as refinement learners substantially improves performance under unreliable pseudo-label supervision.Based on this observation, we propose Refinement-based Noise-conditioned Learning (RNCL), a general framework for semi-supervised medical image segmentation. RNCL trains a refinement model to improve coarse predictions generated by a guide model, and further regulates the influence of guidance by injecting controlled Gaussian noise into the guide predictions during training. This noise-conditioned formulation exposes the refinement model to guidance signals with different degrees of corruption, encouraging adaptive integration of image information and guidance rather than trivial copying.In addition, RNCL incorporates a Feature Fusion with Adaptive Gating (FFAG) module to integrate image features, joint image-guidance features, and feature-level representations from the guide model. Extensive experiments on three public medical image segmentation benchmarks demonstrate that RNCL consistently outperforms state-of-the-art semi-supervised methods under low-label settings, while ablation studies confirm the effectiveness and robustness of each component. The code is accessible at https://github.com/woaierxu/RNCL.
AB - Semi-supervised medical image segmentation aims to reduce annotation costs by exploiting unlabeled data, yet its performance is often limited by unreliable pseudo-label supervision. In existing studies, V-Net and its variants are predominantly adopted as backbone architectures, and most advances focus on improving training strategies rather than exploring architectural diversity. We observe that directly applying classical segmentation models to semi-supervised settings, without task-specific configuration adjustment, often leads to overfitting when models are trained to predict segmentation masks from scratch. Interestingly, our empirical analysis reveals that reformulating the same segmentation models as refinement learners substantially improves performance under unreliable pseudo-label supervision.Based on this observation, we propose Refinement-based Noise-conditioned Learning (RNCL), a general framework for semi-supervised medical image segmentation. RNCL trains a refinement model to improve coarse predictions generated by a guide model, and further regulates the influence of guidance by injecting controlled Gaussian noise into the guide predictions during training. This noise-conditioned formulation exposes the refinement model to guidance signals with different degrees of corruption, encouraging adaptive integration of image information and guidance rather than trivial copying.In addition, RNCL incorporates a Feature Fusion with Adaptive Gating (FFAG) module to integrate image features, joint image-guidance features, and feature-level representations from the guide model. Extensive experiments on three public medical image segmentation benchmarks demonstrate that RNCL consistently outperforms state-of-the-art semi-supervised methods under low-label settings, while ablation studies confirm the effectiveness and robustness of each component. The code is accessible at https://github.com/woaierxu/RNCL.
KW - Feature fusion
KW - Medical image segmentation
KW - Noise conditioning
KW - Refinement learning
KW - Semi-supervised learning
UR - https://www.scopus.com/pages/publications/105035750009
U2 - 10.1016/j.eswa.2026.132365
DO - 10.1016/j.eswa.2026.132365
M3 - Article
AN - SCOPUS:105035750009
SN - 0957-4174
VL - 322
JO - Expert Systems with Applications
JF - Expert Systems with Applications
M1 - 132365
ER -