TY - JOUR
T1 - Robot-Assisted Doppler Optical Coherence Tomography for Intraoperative Evaluation of Microvascular Anastomoses
AU - Li, Xiaochen
AU - Huang, Yong
AU - Liu, Lu
AU - Tong, Danling
AU - Wang, Juyi
AU - Li, Meng
AU - Bai, Yujie
AU - Tong, Dedi
AU - Zhu, Shan
AU - Chen, Shanlin
AU - Hao, Qun
N1 - Publisher Copyright:
© 2026 The Author(s). Advanced Intelligent Systems published by Wiley-VCH GmbH.
PY - 2026/5
Y1 - 2026/5
N2 - Intraoperative assessment of microvascular anastomoses is challenging because vessel patency and hemodynamics can change rapidly and are difficult to judge visually, especially for submillimeter vessels. Here, we present a robot-assisted Doppler optical coherence tomography (DOCT) system that performs autonomous wide-field, three-dimensional imaging of vascular anastomoses intraoperatively. The platform integrates machine-vision–guided vessel localization, adaptive path planning with probe pose adjustment, and continuous C-scan acquisition to generate stitched structural and hemodynamic maps over regions up to 2.2 × 3.5 × 20 (lateral × depth × longitudinal) mm. Quantitative phantom experiments validate Doppler flow sensing and image quality. In rat femoral and tail artery models, the system visualizes clinically relevant indicators—including patency, anastomotic narrowing, hematoma formation, and local flow disturbances—and enables longitudinal tracking of postanastomotic hemodynamic evolution. These results establish robot-assisted DOCT as a potential useful tool for automated, wide-field intraoperative microvascular assessment to support decision-making and training.
AB - Intraoperative assessment of microvascular anastomoses is challenging because vessel patency and hemodynamics can change rapidly and are difficult to judge visually, especially for submillimeter vessels. Here, we present a robot-assisted Doppler optical coherence tomography (DOCT) system that performs autonomous wide-field, three-dimensional imaging of vascular anastomoses intraoperatively. The platform integrates machine-vision–guided vessel localization, adaptive path planning with probe pose adjustment, and continuous C-scan acquisition to generate stitched structural and hemodynamic maps over regions up to 2.2 × 3.5 × 20 (lateral × depth × longitudinal) mm. Quantitative phantom experiments validate Doppler flow sensing and image quality. In rat femoral and tail artery models, the system visualizes clinically relevant indicators—including patency, anastomotic narrowing, hematoma formation, and local flow disturbances—and enables longitudinal tracking of postanastomotic hemodynamic evolution. These results establish robot-assisted DOCT as a potential useful tool for automated, wide-field intraoperative microvascular assessment to support decision-making and training.
KW - Doppler OCT
KW - intraoperative imaging
KW - microvascular anastomosis
KW - robot-assisted DOCT
KW - vascular hemodynamics
UR - https://www.scopus.com/pages/publications/105032162637
U2 - 10.1002/aisy.202501066
DO - 10.1002/aisy.202501066
M3 - Article
AN - SCOPUS:105032162637
SN - 2640-4567
VL - 8
JO - Advanced Intelligent Systems
JF - Advanced Intelligent Systems
IS - 5
M1 - e202501066
ER -